Part Number Hot Search : 
3EVKI CD2025 2SD180 LH28F XR16C8 KIA2431 IRFP442R 2SC51
Product Description
Full Text Search
 

To Download FMP04A2626 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  iec inlet filters f.mh-f.mk-f.ml-f.mm-f.mp-f.mq-f.mr-f.ms series with fuse holder, bipolar switch and voltage selector this series gives a high level of suppression within a compact enclosure. the iec 60320 inlet power entry module combines 1 or 2 fuse holders for us and iec fuses, with a bipolar rocker switch, earth choke and input voltage selector. designed for use in business, consumer, test and medical equipment for international markets. current ratings from 1a to 6a comprehensive range of filter performance options integral single or twin fuse holder optional voltage selector optional earth line choke horizontal or vertical mounting medical versions available approvals electrical specifications rated voltage (v r ): max 250v, 50/60hz rated current (i r ): referred to room temperature = 40? leakage current (i l ): at 220v, 50hz, max value voltage test (2 s .): line to ground 3000vdc or 1800vac line to line 1700vdc climatic category: hpf (25/085/21); temperature range: -25? to +85? bipolar rocker 10(4)a / 250vac (rated current), switches: 50000 on-off operations; values in ( ) relate to the inductive current; inrush current test according to ul 1054 (35a). voltage selector: 110-220vac (f.mh - f.mk - f.ml - f.mm only). mechanical specifications manufacture: metal case with built-in power line connector according to iec 60320, fuse holder for 1 fuse (f.mh. - f.ml. - f.mp. - f.mr) or 2 fuses (f.mk. - f.mm. - f.mq. - f.ms) 5 x 20mm (iec) or 6.3 x 32mm (us), bipolar rocker switch, voltage selector 110/220vac (f.mh - f.mk - f.ml - f.mm only); internal components sealed with self-extinguishing resin. connections: iec 60320 - standard plug (input); faston 6.3 x 0.8mm (output); ground terminal connected to case. mounting: f.mh, f.mk, fml, fmm versions now available in vertical mounting version - (f.**.***.**.**.010) with no approvals. 32 filter range (example pt no. - f.mh.01a.20.25) code i r l 1 l 2 cx 1 cx 2 cy l l r (a) (mh) (mh) (f) (f) (pf) (ma) (m ) 20.- - 2 x 10 2 x 4700 2 x 0.43 01a 24.- - 1 2 x 10 0.22 0.1 2 x 0.003 0.33 30.- - 2 x 22 2 x 4700 2 x 0.43 34.- - 2 x 22 2 x 0.003 21.- - 2 x 2 2 x 4700 2 x 0.43 f.mh. 2a5 25.- - 2.5 2 x 2 0.22 0.1 2 x 0.003 0.33 f.mk. 31.- - 2 x 8 2 x 4700 2 x 0.43 f.mq. 35.- - 2 x 8 2 x 0.003 f.ms. 22.- - 2 x 1 2 x 4700 2 x 0.43 04a 26.- - 4 2 x 1 0.22 0.1 2 x 0.003 0.33 32.- - 2 x 8 2 x 4700 2 x 0.43 36.- - 2 x 8 2 x 0.003 23.- - 2 x 1 2 x 4700 2 x 0.43 06a 27.- - 6 2 x 1 0.22 0.1 2 x 0.003 0.33 33.- - 2 x 2.5 2 x 4700 2 x 0.43 37.- - 2 x 2.5 2 x 0.003 20.- - 2 x 10 2 x 4700 2 x 0.43 01a 24.- - 1 2 x 10 0.65 0.22 0.1 2 x 0.003 0.33 30.- - 2 x 22 2 x 4700 2 x 0.43 34.- - 2 x 22 2 x 0.003 21.- - 2 x 2 2 x 4700 2 x 0.43 f.ml. 2a5 25.- - 2.5 2 x 2 0.65 0.22 0.1 2 x 0.003 0.33 f.mm. 31.- - 2 x 8 2 x 4700 2 x 0.43 f.mp. 35.- - 2 x 8 2 x 0.003 f.mr. 22.- - 2 x 1 2 x 4700 2 x 0.43 04a 26.- - 4 2 x 1 0.65 0.22 0.1 2 x 0.003 0.33 32.- - 2 x 8 2 x 4700 2 x 0.43 36.- - 2 x 8 2 x 0.003 23.- - 2 x 1 2 x 4700 2 x 0.43 06a 27.- - 6 2 x 1 0.65 0.22 0.1 2 x 0.003 0.33 33.- - 2 x 2.5 2 x 4700 2 x 0.43 37.- - 2 x 2.5 2 x 0.003 no approvals, circuit diagram d no approvals, circuit diagram c not applicable to fmp,fmr .010 = vertical mounting option (addition to standard pt no.) 25 = rocker switch 26 = illuminated rocker switch h = 1 fuse k = 2 fuses l = 1 fuse + earth choke m = 2 fuses + earth choke p = 1 fuse, single pole switch (no voltage selector) q = 2 fuses, single pole switch (no voltage selector) r = 1 fuse, double pole switch (no voltage selector) s = 2 fuses, double pole switch (no voltage selector) circuit diagram: a b d c
33 iec inlet filters f.mh-f.mk-f.ml-f.mm-f.mp-f.mq-f.mr-f.ms series dimensions (mm) and connections circuit diagram a b c d f.mh, f.mk, f.mq, f.ms, f.mp, f.mr.01a f.m-.01a ?? f.ml, f.mm, .01a f.mh, f.mk, f.mq, f.ms, f.mp, f.mr .2a5 f.m-.2a5 ?? f.ml, f.mm.2a5 f.mh, f.mk, f.mq, f.ms, f.mp, f.mr .04a f.m-.04a ?? f.ml, f.mm.04a f.mh, f.mk, f.mq, f.ms, f.mp, f.mr .06a f.m-.06a ?? f.ml, f.mm.06a insertion loss (typical): asymmetrical (line to ground) with cy asymmetrical (with earth inductor) ??? symmetrical (line to line)


▲Up To Search▲   

 
Price & Availability of FMP04A2626

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X